NPM20
Intelligent High-frequency
DC Power Supply System
A brand new power supply system integrating digital control, protection and management to provide stable operating power for DC circuits.
NPM20 series intelligent high-frequency DC power supply system is mainly used in power grid, power generation and other fields. As a DC uninterrupted power supply for all automatic electric power systems, communication systems, remote execution systems, switch opening and closing, relay protection, automatic devices and signaling devices of high-voltage circuit breaker.
large-size color touch screen makes human-machine operation more convenient.
The system is equipped with RS485/RS232 communication interface and adheres to Modbus-RTU protocol, which can be accessed to the back-end system to realize intelligent monitoring.
High-frequency DC power supply module adopts N+1 redundant design and high-frequency resonant soft-switching technology, reducing the loss and extending the service life.
Uses the battery of well-known brand, and the service life is up to 100,000 hours (1500 times).
the rectifier module utilizes advanced soft-switching conversion technology and built-in CPU technology, with low voltage distortion, high efficiency, high accuracy of voltage and current stabilization and low ripple coefficient.
The charging module can be hot-swapped, which greatly reduces the average maintenance time, so that the device is able to monitor the insulation of the system in real time to ensure system and personal safety.
Category | Name | Indicator | |
220V Series | 110V Series | ||
Input parameters | Input voltage | AC80-285V or AC380V±20% | |
Frequency | 50Hz±10% | ||
Power factor | ≧0.92 | ≧0.92 | |
Output parameter | Float voltage | 176~260Vdc | 88~130Vdc |
Equalizing charge | 220~286Vdc | 110~143Vdc | |
Ripple coefficient | ≤±0.5%(typical value 0.1%) | ≤±0.5%(typical value 0.1%) | |
Voltage stabilization accuracy | ≤±0.5%(typical value 0.1%) | ≤±0.5%(typical value 0.1%) | |
Current stabilization accuracy | ≤±0.5%(typical value 0.1%) | ≤±0.5%(typical value 0.1%) | |
Equalizing unbalance | ≤±3%(50%-100% rated load) | ≤±3%(50%-100% rated load) | |
Efficiency | 95% (single module) | 95% (single module) | |
Protection parameters | Input overvoltage switching point | 456±5Vac | 456±5Vac |
Input undervoltage switching point | 304±5Vac | 304±5Vac | |
Charging module output undervoltage alarm | 196V | 99V | |
Insulation characteristics | Output-to-ground insulation | 2kVac, current leakage ≤30mA, 1min, no arcing |
2kVac, current leakage ≤30mA, 1min, no arcing |
Input-to-ground insulation | |||
Input to output ground insulation | |||
Insulation resistance | ≥10MΩ | ≥10MΩ | |
Application environment | Operating temperature | -10℃~+45℃ | |
Storage temperature | -40℃~+60℃ (without battery) | ||
Humidity | Daily average ≤95%, Monthly average ≤90% | ||
Other characteristics | Noise | Self-cooling ≤40db | |
Protection degree | ≥IP30 | ||
Heat dissipation mode | Air-cooling/Self-cooling | ||
Battery capacity | 20AH~2000AH | ||
Battery life | 100,000 hours |
NPM20 | 100AH | 2 | G | D2 | Optional functions |
Product code | Capacity specification | Number of cabinet panels | Installation method | Output voltage | Function code |
NPM20: Intelligent High-frequency DC Power Supply System |
20AH 24AH 40AH 65AH 100AH |
1: one panel 2: two panels 3: three panels |
No code: None:Floor-standing G:Wall-mounted |
D2: DC220V D1: DC110V D4: DC48V |
K: Switching detection module C: Battery inspection module F:Branch circuit insulation detection module N:Inverter module |
NPM20 Intelligent High-frequency DC Power Supply System
Input parameters:
Input voltage:AC80-285V or AC380V±20%;Frequency:50Hz±10%;Power factor: ≧0.92;
Output parameter:
Float voltage:176~260Vdc;Equalizing charge:220~286Vdc;Ripple coefficient:≤±0.5%(typical value 0.1%);Voltage stabilization accuracy :≤±0.5%(typical value 0.1%);Current stabilization accuracy :≤±0.5%(typical value 0.1%);Equalizing unbalance: ≤±3%(50%-100% rated load);Efficiency:95% (single module);
Protection parameters:
Input overvoltage switching point:456±5Vac;Input undervoltage switching point:304±5Vac;Charging module output undervoltage alarm:196V;
Insulation characteristics:
Output-to-ground insulation/Input-to-ground insulation/Input to output ground insulation:2kVac, current leakage ≤30mA,1min, no arcing;Insulation resistance:≥10MΩ;
Application environment:
Operating temperature:-10℃~+45℃;Storage temperature:-40℃~+60℃ (without battery);Humidity:Daily average ≤95%, Monthly average ≤90%;
Other characteristics:
Noise:Self-cooling ≤40db;Protection degree:≥IP30;Heat dissipation mode:Air-cooling/Self-cooling;Battery capacity :20AH~2000AH;Battery life:100,000 hours;
Input parameters:
Input voltage:AC80-285V or AC380V±20%;Frequency:50Hz±10%;Power factor: ≧0.92;
Output parameter:
Float voltage:88~130Vdc;Equalizing charge:110~143Vdc;Ripple coefficient:≤±0.5%(typical value 0.1%);Voltage stabilization accuracy :≤±0.5%(typical value 0.1%);Current stabilization accuracy :≤±0.5%(typical value 0.1%);Equalizing unbalance: ≤±3%(50%-100% rated load);Efficiency:95% (single module);
Protection parameters:
Input overvoltage switching point:456±5Vac;Input undervoltage switching point:304±5Vac;Charging module output undervoltage alarm:99V;
Insulation characteristics:
Output-to-ground insulation/Input-to-ground insulation/Input to output ground insulation:2kVac, current leakage ≤30mA,1min, no arcing;Insulation resistance:≥10MΩ;
Application environment:
Operating temperature:-10℃~+45℃;Storage temperature:-40℃~+60℃ (without battery);Humidity:Daily average ≤95%, Monthly average ≤90%;
Other characteristics:
Noise:Self-cooling ≤40db;Protection degree:≥IP30;Heat dissipation mode:Air-cooling/Self-cooling;Battery capacity :20AH~2000AH;Battery life:100,000 hours;
Product code:NPM20:Intelligent High-frequency DC Power Supply System
Capacity specification:20AH,24AH,40AH,65AH,100AH
Number of cabinet panels:1: one panel , 2: two panels , 3: three panels
Installation method:None:Floor-standing,G:Wall-mounted
Output voltage:D2: DC220V,D1: DC110V,D4: DC48V
Function code:K: Switching detection module C: Battery inspection module ,F:Branch circuit insulation detection module,N:Inverter module